itk-logo
Globe

JOB OFFERS

Job offers

We offer challenging tasks – at all career levels. At the same time, you can develop yourself optimally. And feel comfortable.

Have we aroused your interest? Then send us your application. We look forward to receiving your application!

 

Current vacancies

Our employees are the basis of our success. If you see your perspective in a dynamic, innovative working environment with flat structures and pleasant teamwork, then please send your application documents to:

ITK Dr. Kassen GmbH
Claudia Dern
At the Eberacker 3
35633 Lahnau

c.dern@itknet.de

Here you can find the job offers:

Apprenticeship with ITK

Would you like to learn something practical after leaving school and experience what everyday working life in a company is like? Then you should think about vocational training. The most important prerequisite for starting a 3.5-year apprenticeship with us is a good to very good secondary school diploma, or even a high school diploma. You should also have a fair amount of initiative.

We are looking for trainees for the following professions:

• Mechatronics technician
• Industrial mechanic
• Machinist

It is important to us that our future trainees enjoy a high quality standard during the entire training period. We therefore work very closely with the company Pro Zukunft- Aus- und Weiterbildung e.K. from Wetzlar.

After you have successfully completed your training, we would like to retain you in our company for the long term.

Temporary staff

We are always looking for temporary workers in the field of electronics production, mechanical assembly of individual components or positioning systems. You should have a certain level of manual skills and an interest in the manufacture of technical products. Ideally, you are flexible in terms of time and willing to consider hourly working models.

Trainees and working students

Are you studying a MINT subject and would like to gain your first practical experience? With a student internship at ITK you will gain an insight into the different areas of our company and find out which activities suit you. For the development area, you should bring at least four weeks of time with you and have completed your basic studies, because you will implement a small project during your internship. The same applies to internships in the commercial area: four weeks is the minimum.

If you want to get a taste of practical experience over a longer period of time during your studies and lay the foundation for a later career entry, ITK offers you a job as a working student. Ideally, you will have already completed an internship with us – in mechanics, electronics, hardware or software development. As a working student, you should have at least eight hours per week during the semester or several weeks at a time during the semester break. This allows us to plan better and gives you a sound insight into our processes.

Unsolicited application

You have not found a suitable position for you among our vacancies? You are welcome to send an unsolicited application to join ITK Dr. Kassen GmbH by e-mail to Claudia Dern c.dern@itknet.de 

SIE MÖCHTEN AUF DEM LAUFENDEN BLEIBEN?

DANN ABONNIEREN SIE UNSEREN NEWSLETTER!

You will find information on data processing in our privacy policy.

Sie interessieren sich für unsere Produkte?
Sie möchten mit uns gemeinsam nach einer Lösung
Ihrer Aufgabe suchen?
Dann schreiben Sie uns. 
Wir freuen uns auf einen konstruktiven Austausch!

Hinweise zur Datenverarbeitung erhalten Sie in unserer Datenschutzbestimmung.

YOU WANT TO STAY UP TO DATE?

THEN SUBSCRIBE TO OUR NEWSLETTER!

You will find information on data processing in our privacy policy.

Are you interested in our products?
Would you like to work with us to find a solution
for your task?
Then contact us. 
We look forward to a constructive exchange!

You will find information on data processing in our privacy policy.

Pollux OEM-Variants

Pollux OEM

Main features 

• Available as built-in variants without housing

Cross Stage FCS100

Kreuztische

Technical Data

Parameter

Unit

Typical performance characteristics 

Repeatability

µm

0.1 … 50

Traversing speed

mm/s

0.01 … 5000

Acceleration

mm/s2

100 mm/s2 … 5 g

Position resolution

nm

5 … 1000

Travel path

mm

10 … 500

LMT Microscope Stages

LMT

Technical Data

Parameter

Unit

Typical performance features

Travel speed 

mm/s

0.1 … 500

Acceleration

mm/s2

≤ 1000

Repeat accuracy

µm

different classes

Position resolution

nm

5

Travel range

mm

50 x 50 … 205 x 205

LMP linear magnetisation machines

LMP ITK

Technical Data

Parameters

Typical performance characteristics 

Scale lengths

50 - 5000 mm

Materials

hard magnetic, elastomer-bonded and plastic bonded material

Track widths 

1 - 5 mm

Number of tracks

1 - 3, several coded tracks possible 

Period lengths

500 - 5000 µm

Accuracy

up to the sub-µm range (compensated)

Resolution

in the nanometre range

Writing method

digital or analogue

Software

customised operating and evaluation software 

Quality inspection

scale measurement on the same system

Typical operating conditions

industrial continuous operation (24/7)

Labelling

each scale can be individually marked

Rotary Stage FRS 200

Rundtisch frs200_02

Technical Data

Parameter

Unit

Typical performance characteristics 

Repeatability

arcsec

2 … 36

Axial runout

µm

3 … 10

Radial runout

µm

3 … 20

Mass to be moved

kg

5 … 10

Hollow shaft

mm

40 … 50

Diameter

mm

100, 200

Stepper motors

Schrittmotorengruppe

Main features 

We can offer you stepper motors in a wide range of performance classes and torque curves. It does not matter whether in an industrial environment in clean rooms or in a dirty environment.

  • Torque curve can be individually adapted
  • High torque
  • Stronger magnetic field achieves high dynamics with the same rotor moment of inertia
  • Motor connection adapter on request
  • Dampers at the second shaft end improve the synchronisation characteristics
  • ITK’s unique control technology greatly minimises resonance frequencies
  • Suitable for clean rooms

Alpha Torque servomotors

Alphat_Gleichstrommotoren

Key features 

  • High torques over the entire speed range
  • Speed max. 10 r/s
  • Precise MR measuring system for absolute measuring
  • Multiturn functionality up to max. 16,000 revolutions
  • Protection class IP65

Rotary Stage RS 180

Rundtisch rs 180

Technical Data

Parameter

Unit

Typical performance characteristics 

Repeatability

arcsec

2 … 36

Axial runout

µm

3 … 10

Radial runout

µm

3 … 20

Mass to be moved

kg

5 … 10

Hollow shaft

mm

40 … 50

Diameter

mm

50 … 300

Gantry Positioning System FBS

v

Technical Data

Parameter

Unit

Typical performance characteristics 

Load capacity

kg

0.5 … 5

Travel speed in X & Y

m/s

0.25 ... 1

Acceleration in X & Y

m/s2

0.5 … 10

Repeatability bidirectional

µm

≤ ±1

Positioning accuracy bidirectional

µm

≤ ±20 … ≤ ±80

Resolution

nm

500

RMP Rotary Magnetisation Machines

RMP itk

Technical Data

Parameter

Typical performance characteristics 

Scale diameter

3.5 - 500 mm (standard) 

Scale materials

hard magnetic, elastomer and plastic bonded material

Coding placement 

optional radial or axial description

Number of lines

freely selectable

Number of tracks:

several coded tracks possible; reference marks (polarisation adjustable)

Repeatability:

from 5 arcsec (depending on reference measuring system and material) 

Resolution

up to 0.5 arcsec

Writing method

digital or analogue

Software 

customised operating and evaluation software optional 

Quality inspection:

scale measurement on the same system optional

Typical conditions of use

industrial continuous operation (24/7)

Marking

each scale can be individually labelled.

Linear Stage FLS100

Lineartische

Technical Data

Parameter

Unit

Typical performance characteristics 

Repeat accuracy

µm

0.1 … 50

Traversing speed

mm/s

0.01 … 5000

Acceleration

mm/s2

100 mm/s2 … 5 g

Position resolution

nm

5 … 1000

Travel path

mm

10 … 10.000

Linear Stage ST9 Eco

ST9 Eco

Technical Data

Parameter

Unit

Typical performance characteristics 

Repeatability

µm

0.1 … 50

Traversing speed

mm/s

0.01 … 5000

Acceleration

mm/s2

100 mm/s2 … 5 g

Position resolution

nm

5 … 1000

Travel path

mm

10 … 10000

Cross Stage KS15

kl12

Technical Data

Parameter

Unit

Typical performance characteristics 

Repeatability

µm

0.1 … 50

Traversing speed

mm/s

0.01 … 5000

Acceleration

mm/s2

100 mm/s2 … 5 g

Position resolution

nm

5 … 1000

Travel path

mm

10 … 500

Pollux-Box

Pollux Box

Main features 

  • Control and motors as separate positioning unit
  • High flexibility

Measuring systems

MR_Messtechnik_Komplett

Key features 

  • Magnetically coded scales allow the use of a wide variety of components (scale carriers)
  • Incremental or absolute measuring systems for determining the position are possible
  • Position resolution of 5 nm achievable
  • OptoMag evaluation electronics provide an industry-standard output signal of 1 Vpp/ 20 µm period length. Other period lengths on request
  • Adaptation to any control system possible
  • Specially designed for use in dirty environments
  • Scale encoding is carried out very precisely with a laser interferometer
  • Customer-specific scales can be realised
  • Evaluation electronics and sensor available separately (in case of space problems) or integrated
  • Vacuum compatible

Hydra-Controllers

Hydra Start

Technical Data

Parameter

Unit

Typical performance characteristics

DC link voltage

Vac

0 … 48

Max. Phase current

A

2,5 … 50

Supported motor types 

mm/s2

Linear-, Stepper-, Voice Coil- Servo-, DC-Motoren

Position resolution

nm

5 … 1000

Real-time trigger


Interface compatibility


Manual control units


Safety functions 

Hydra XP – the most powerful

Hydra Xp

Main features

  • 4 axes in 1 housing
  • Power supply: 48 volts
  • Power: 1600 watts
  • Phase current: max. 50 A

Hydra RM – fits in any control cabinet

Hydra RM

Main features

  • 4 axes in 1 housing
  • Power supply: 24 V / 48 V
  • Power: 1000 watts
  • Phase current: max. 15 A

Hydra TT – Table version

Hydra Start

Main features

  • 2-axis
  • Power supply: 24 V / 48V
  • Power: 300 watts
  • Current in 2-phase operation: max. 10 A
  • Current in 3-phase operation: max. 5 A
  • Interfaces: CAN, RS232, Ethernet

Hydra CM – with compact design

Hydra CM

Main features 

  • 2-axis
  • Power supply: 24 V / 48 V
  • Power: max. 500 W
  • Phase current: 10 A (24 V) / 5 A (48 V)
  • External 24 V / 48 V power supply unit
  • Suitable for mounting in control cabinet
  • Compact design enables mounting directly on positioning mechanisms

Hydra DT – with Joystick

Hydra DT

Main features 

  • 2-axis
  • Power supply: 24 V / 48 V
  • Power: 150 watts
  • Phase current: max. 10 A (24V) / 5 A (48V)
  • 6 freely programmable function keys

Andromeda-Controllers

Andromeda

Technical Data

Parameter

Unit

Typical performance characteristics

DC link voltage

Vac

0 … 48

Max. Phase current

A

2,5 … 50

Supported motor types 

mm/s2

Linear-, Stepper-, Voice Coil- Servo-, DC-Motoren

Position resolution

nm

5 … 1000

Real-time trigger


Interface compatibility


Manual control units


Safety functions 

Andromeda CM

Andromeda CM

Main features 

  • Up to 6 axes
  • Power supply: 24 V to 48 V
  • Power: 200 W
  • Phase current: 3 A

Andromeda TT – Table version

Andromeda tt

Main features 

  • 3 axis
  • DC link voltage: 24 V / 48V
  • Power: 200 W
  • Phase current: 5 A 
  • Interfaces: CAN, RS232, Ethernet, USB

Andromeda Base Controller

Andromeda base

Main features 

  • 2-axis
  • Power supply: 24 V / 48V
  • Power: 300 watts
  • Current in 2-phase operation: max. 10 A
  • Current in 3-phase operation: max. 5 A
  • Interfaces: CAN, RS232, Ethernet

Pollux-Controllers

Pollux

Technical Data

Parameter

Unit

Typical performance characteristics

DC link voltage

Vac

0 … 48

Max. Phase current

A

2,5 … 50

Supported motor types 

mm/s2

Linear-, Stepper-, Voice Coil- Servo-, DC-Motoren

Position resolution

nm

5 … 1000

Real-time trigger


Interface compatibility


Manual control units


Safety functions 

Gantry Positioning System PT15

Gantrysystem

Technical Data

Parameter

Unit

Typical performance characteristics 

Travel speed in X

m/s

0.5 … 2.5

Travel speed in Y

m/s

0.5 … 0.8

Acceleration in X

m/s2

5 … 50

Acceleration in Y

m/s2

0.5 … 5

Repeatability bidirectional

µm

≤ ±0.5 … ≤ ±2.5

Positioning accuracy bidirectional

µm

≤ ±10 … ≤ ±50

Resolution 

nm

50 … 500